In industrial Internet of Things applications, Kingview, as a powerful monitoring configuration software, is widely used in industrial automation systems. Meanwhile, PUSR Lte modems, as a key device for data transmission, is responsible for data interaction between field equipment and remote servers. To achieve effective communication between the two, correct configuration is required, and some key considerations need to be taken into account. This article aims to explain the configuration steps and precautions for Kingview and PUSR Lte modems communication to traditional industries.
1. Lte modems Device Configuration
First, ensure that the PUSR Lte modems device has been correctly installed and connected to the field equipment. According to the Lte modems's manual or configuration guide, set the communication parameters of the Lte modems, such as baud rate, data bits, stop bits, etc., to ensure compatibility with the Kingview software.
Open the Kingview software and create a new engineering project or open an existing one. In the project, add the communication device driver corresponding to the Lte modems equipment. Select the device driver suitable for PUSR Lte modems from the Kingview's device driver library.
Configure the communication parameters in Kingview to ensure consistency with the settings of the Lte modems device. This includes serial port selection, baud rate, data bits, stop bits, parity bits, etc. Ensuring the correctness of these parameters is crucial for establishing a stable communication connection.
Define data variables in Kingview that correspond to the data transmitted by the Lte modems equipment. These variables will be used to receive and send data, enabling data interaction between field equipment and the monitoring system.
After completing the configuration, perform a communication test to ensure that the connection between Kingview and Lte modems is normal. Verification can be done by sending test instructions or reading device status.
Ensure that the communication protocols supported by Kingview software are compatible with the PUSR Lte modems device. Different Lte modems devices may adopt different communication protocols, so attention should be paid to matching when selecting device drivers.
The communication parameters between Kingview and Lte modems must be consistent, including serial port settings, baud rate, data format, etc. Any inconsistency may lead to communication failure or data errors.
The stability of communication is greatly influenced by the network environment. Ensure that the network environment where the Lte modems device is located is stable and reliable, avoiding network fluctuations or interruptions that may affect communication.
When configuring communication, data security and protection measures should be considered. For example, security mechanisms such as data encryption and access control can be set up to prevent data leakage or unauthorized access.
In the process of communication, if communication failures or data abnormalities are encountered, fault troubleshooting and handling should be carried out promptly. Log files, debugging information, and other methods can be used to locate the cause of the problem and take corresponding measures to address it.
The communication configuration between Kingview and PUSR Lte modems requires attention to device compatibility, consistency of parameter settings, stability of the network environment, and data security and protection. Through correct configuration and compliance with the precautions, stable and reliable communication between the two can be ensured, providing strong support for the operation of industrial automation systems.